When the depth of a beam exceeds side face reinforcement is provided?

When the depth of a beam exceeds side face reinforcement is provided?

According to IS: 456 – 2000, side-face reinforcement should be provided when the depth of the web of a beam exceeds. 650 mm. 700 mm.

When depth of beam exceeds 750 mm than percentage of side reinforcement IOF Web area is?

0.1\%
Side face reinforcement in the web of the beam provided when the depth of the web in a beam exceeds 750 mm shall not be less than 0.1\% of the web area, distributed equally on two faces at a spacing not exceeding 300 mm or web thickness, whichever is less.

READ ALSO:   Who wore number 89 for the Bears?

Which of the beam with following depth will require side face reinforcement?

Side face reinforcement in the web of the beam is provided when the depth of the web in a beam exceeds 750 mm. (0.1\% of the web area and shall be distributed equally on two faces at a spacing not exceeding 300 mm or web thickness whichever is less).

When the depth of the beam exceed by 750 mm then?

When depth of web in a beam exceeds 750 mm, side face reinforcement @ 0.1 percent of web area should be provided on each face. 3. The nominal spacing of main bars in a slab should not exceed three times the effective depth of a solid slab or 300 mm, whichever is smaller.

When side face reinforcement is provided in a beam?

Beams exceeding the depth of 750 mm and subjected to bending moment and shear shall have side face reinforcement. However, if the beams are having torsional moment also, the side face reinforcement shall be provided for the overall depth exceeding 450 mm.

READ ALSO:   Why IIT Bombay is most preferred?

How do you calculate side face reinforcement in footing?

  1. Side face reinforcements are provided when.
  2. In both the cases side face reinforcement= 0.1 \% of total cross section of beam i.e.
  3. Asf= 0.1 \% of B*D where.
  4. B- width of beam.
  5. D- overall depth of beam.
  6. Moreover side face reinforcements are equally distributed on both the faces.
  7. For more details refer IS CODE 456.

What is side face reinforcement of beam?

Beams exceeding the depth of 750 mm and subjected to bending moment and shear shall have side face reinforcement. The total area of side face reinforcement shall be at least 0.1 per cent of the web area and shall be distributed equally on two faces at a spacing not exceeding 300 mm or web thickness, whichever is less.

What is side face reinforcement of Beam?